Model
Item |
PM-5000GT
|
|
Inverter
Technology |
Conversion Mode |
Sine-wave, Current
source, High frequency PWM |
|
Isolation Method
|
Transformer-less
Design * |
|
DC Input Data
|
|
|
Nominal DC Voltage
|
360 VDC |
|
Max. DC input
Voltage |
500 VDC |
|
Working range |
120VDC~500VDC **
|
|
Max DC input current
(Each MPPT Tracker) |
17.65 Amp |
|
MPPT Range |
150 VDC ~ 450 VDC
|
|
MPPT Tracker |
2 |
|
AC Output Data
|
|
|
Nominal AC Power
|
5000 |
|
Max. AC Power |
5300 |
|
Nominal AC Voltage
|
AC 230V |
|
Output Connect
Method |
1-Phase / 2-Wires(L,
N, G) or 1-Phase / 3-Wires(L1, L2, G) |
|
AC Voltage Rang |
184~264.5Vac(Base on
230 Vac) |
|
Nominal AC Current
|
21.7Amp |
|
Frequency |
50/60Hz
Auto-Selection (47.5 ~ 50.2 Hz or 59.3 ~ 60.5 Hz) |
|
Power Factor |
>0.99 with nominal
AC current |
|
Current Distortion
|
Total Harmonic
current : Less than 5%
Single Harmonic current : Less than 3% |
|
Efficiency Data
|
|
|
Max. efficiency |
>96% |
|
Euro efficiency |
>94% |
|
CEC efficiency |
>94% |
|
Environmental
|
|
|
Operating
Temperature |
-25 °C ~ + 50 °C
|
|
-13 °F ~ 122 °F |
|
Humidity |
0 to 90%(Without
condensation) |
|
Altitude |
0 ~ 2000 M / 0 ~
6600 ft |
|
Mechanical
|
|
|
Dimensions
(H x W x D in mm ) |
455 x 510 x 170 |
|
Weight (Kgs / Lbs)
|
28 / 62 |
|
Protection Class
|
IP65, outdoor |
|
Cooling |
Free Convection |
|
AC Connector |
Terminal |
|
DC Connector |
Multi-Contact |
|
Communication
|
|
|
Communication
Interface |
RS232 |
|
USB, RS485, Dry
contact, TCP/IP |
|
Front Panel |
|
|
LCD |
Boost input Voltage/Boost input Current/Boost input Power/AC
output Voltage /AC output frequency/AC output current /AC output
power/AC Energy yield/Inner Temperature/Heat sink Temperature
/Status message/ Error message |
|
LED |
Leakage current
fault or DC input isolation fault |
|
Spec. of Utility is
not matches with the Utility specifications of the inverter |
|
Solar Cell power is
greater or smaller than sleep power |
|
Key Pad |
UP key/ Down key/
Function key/ Enter key |
|
Protection
|
|
|
Utility |
Over/under Voltage,
Over/under Frequency,
Ground fault, DC Isolation fault |
|
Islanding operation
detection |
Passive : Voltage
phase jump detection
Active : Reactive power control |
|
Over Temperature |
reduced output power |
|
Certification |
|
|
Safety |
VDE 0126-1-1,
EN50178, IEC62103 |
|
UL1741, IEEE1547 |
|
EMI/EMC |
EN 6 1000-6-1, EN 6
1000-6-2, EN 6 1000-6-3, EN 6 1000-6-4 |