Model
Item |
DE-4000GT
|
|
Inverter
Technology |
Conversion
Mode |
Sine-wave,
Current source, High frequency PWM |
|
Isolation
Method |
Transformer-less Design * |
|
DC Input
Data |
|
|
Nominal DC
Voltage |
360 VDC |
|
Max. DC
input Voltage |
500 VDC |
|
Working
range |
120VDC~500VDC ** |
|
Max DC input
current
(Each MPPT Tracker) |
14 Amp |
|
MPPT Range
|
150 VDC ~
450 VDC |
|
MPPT Tracker
|
2 |
|
AC Output
Data |
|
|
Nominal AC
Power |
4000 |
|
Max. AC
Power |
4200 |
|
Nominal AC
Voltage |
AC 230V |
|
Output
Connect Method |
1-Phase /
2-Wires(L, N, G) or 1-Phase / 3-Wires(L1, L2, G) |
|
AC Voltage
Rang |
184~264.5Vac(Base on 230 Vac) |
|
Nominal AC
Current |
17.4Amp |
|
Frequency
|
50/60Hz
Auto-Selection (47.5 ~ 50.2 Hz or 59.3 ~ 60.5 Hz) |
|
Power Factor
|
>0.99 with
nominal AC current |
|
Current
Distortion |
Total
Harmonic current : Less than 5%
Single Harmonic current : Less than 3% |
|
Efficiency Data |
|
|
Max.
efficiency |
>96% |
|
Euro
efficiency |
>94% |
|
CEC
efficiency |
>94% |
|
Environmental |
|
|
Operating
Temperature |
-25 °C ~ +
50 °C |
|
-13 °F ~ 122
°F |
|
Humidity
|
0 to
90%(Without condensation) |
|
Altitude
|
0 ~ 2000 M /
0 ~ 6600 ft |
|
Mechanical |
|
|
Dimensions
(H x W x D in mm ) |
455 x 510 x
170 |
|
Weight (Kgs
/ Lbs) |
28 / 62 |
|
Protection
Class |
IP65,
outdoor |
|
Cooling |
Free
Convection |
|
AC Connector
|
Terminal
|
|
DC Connector
|
Multi-Contact |
|
Communication |
|
|
Communication Interface |
RS232 |
|
USB, RS485,
Dry contact, TCP/IP |
|
Front
Panel |
|
|
LCD |
Boost input
Voltage/Boost input Current/Boost input Power/AC output
Voltage /AC output frequency/AC output current /AC
output power/AC Energy yield/Inner Temperature/Heat sink
Temperature /Status message/ Error message |
|
LED |
Leakage
current fault or DC input isolation fault |
|
Spec. of
Utility is not matches with the Utility specifications
of the inverter |
|
Solar Cell
power is greater or smaller than sleep power |
|
Key Pad |
UP key/ Down
key/ Function key/ Enter key |
|
Protection |
|
|
Utility |
Over/under
Voltage, Over/under Frequency,
Ground fault, DC Isolation fault |
|
Islanding
operation detection |
Passive :
Voltage phase jump detection
Active : Reactive power control |
|
Over
Temperature |
reduced
output power |
|
Certification |
|
|
Safety |
VDE
0126-1-1, EN50178, IEC62103 |
|
UL1741,
IEEE1547 |
|
EMI/EMC |
EN 6
1000-6-1, EN 6 1000-6-2, EN 6 1000-6-3, EN 6 1000-6-4 |